DESCRIPTION | DWG FORMAT | PDF FORMAT |
Standard Curb and Gutter | C-1 | C-1 |
Standard Curb | C-2 | C-2 |
Rolled Curb and Gutter | C-3 | C-3 |
Median Curb and Gutter | C-4 | C-4 |
Sidewalk Joints & Sections | C-5 | C-5 |
Standard Driveway Approach w/ Park Strip | C-6 | C-6 |
Standard Driveway Approach w/o Park Strip | C-7 | C-7 |
Standard Driveway Approach w/o Park Strip | C-8 | C-8 |
Driveway Approach with Culvert | C-9 | C-9 |
Depressed Approach | C-10 | C-10 |
Commercial Approach | C-11 | C-11 |
Commercial Approach with Grassy Swale | C-12 | C-12 |
Driveway Approach Locations and Widths | C-13 | C-13 |
Pedestrian Ramp | C-14 | C-14 |
Cross Gutter | C-15 | C-15 |
Inlet Apron | C-17 | C-17 |
Sidewalk Repair Ramping at Trees | C-18 | C-18 |
Sidewalk Repair Diversion at Trees | C-19 | C-19 |
DESCRIPTION | DWG FORMAT | PDF FORMAT |
Street Name Sign Location | M-1 | M-1 |
Typical Street Name Sign Details | M-2 | M-2 |
Typical Street Sections, Pg 1 | M-4 | M-4 |
Typical Street Sections, Pg 2 | M-5 | M-5 |
Chain Link Fence | M-7 | M-7 |
Signature Block | M-10 | M-10 |
Trench Cut Pavement Repair | M-11 | M-11 |
Pedestal Mount Light Standard | M-13 | M-13 |
Street Lighting Notes | M-15 | M-15 |
Erosion/Sed. Control Notes, Pg 1 | M-16 | M-16 |
Erosion/Sed. Control Notes, Pg 2 | M-17 | M-17 |
Stabilized Construction Entrance | M-18 | M-18 |
Inlet Protection | M-19 | M-19 |
Silt Fence | M-20 | M-20 |
Utility Locations | M-21 | M-21 |
General Plan Notes, Pg 1 | M-22 | M-22 |
General Plan Notes, Pg 2 | M-23 | M-23 |
Pavement Notes, Pg 1 | M-24 | M-24 |
Pavement Notes, Pg 2 | M-25 | M-25 |
Water System Notes | M-27 | M-27 |
Sewer System Notes, Pg 1 | M-28 | M-28 |
Sewer System Notes, Pg 2 | M-29 | M-29 |
Straw Bale Dike | M-30 | M-30 |
Pavement Design Standards | M-31 | M-31 |
Pavement Marking Notes | M-32 | M-32 |
Storm System Notes | M-33 | M-33 |
Multi-Use Path | M-34 | M-34 |
Removable Bollard | M-35 | M-35 |
Crosswalk Striping | M-36 | M-36 |
Bike Lane Striping | M-37 | M-37 |
Bike Lane Markings | M-38 | M-38 |
Pavement Markings | M-39 | M-39 |
Gravel Alley Detail | M-40 | M-40 |
Curb Installation Pavement Repair | M-41 | M-41 |
Fire Lane Striping and Signage | M-42 | M-42 |
Fire Access Requirements | M-43 | M-43 |
DESCRIPTION | DWG FORMAT | PDF FORMAT |
Standard Sewer Manhole | SS-1 | SS-1 |
Shallow Manhole Terminus/Laterals | SS-1A | SS-1A |
Internal Drop Sewer Manhole | SS-2 | SS-2 |
Doghouse Manhole | SS-3 | SS-3 |
New Manhole Thickened Collar | SS-4A | SS-4A |
Existing Manhole Thickened Collar | SS-4B | SS-4B |
Manhole Frame and Cover | SS-5 | SS-5 |
Sewer Service Laterals | SS-6 | SS-6 |
Sewer Service Lateral Markers | SS-7 | SS-7 |
Sewer Tapping Saddle | SS-8 | SS-8 |
Sewer Trench and Backfill Detail | SS-9 | SS-9 |
Force Main Locating Wire Box | SS-10 | SS-10 |
Temporary Tee Sewer Extension | SS-11 | SS-11 |
DESCRIPTION | DWG FORMAT | PDF FORMAT |
Catch Basin, Type 1 | SD-1 | SD-1 |
Grate Frame, Type 1 | SD-2 | SD-2 |
Grate Frame, Type 2 | SD-3 | SD-3 |
Catch Basin Grate - 2 way | SD-4A | SD-4A |
Catch Basin Grate - 1 way | SD-4B | SD-4B |
Catch Basin Installation Detail | SD-5 | SD-5 |
Type A Drywell | SD-6A | SD-6A |
Type B Drywell | SD-6B | SD-6B |
Residential Swale | SD-7 | SD-7 |
Pipe Bedding and Backfill for Storm Drains | SD-8 | SD-8 |
Curb Inlet Box, Type 1 | SD-9 | SD-9 |
Curb Inlet Box, Type 2 | SD-10 | SD-10 |
Swale Drain | SD-11 | SD-11 |
DESCRIPTION | DWG FORMAT | PDF FORMAT |
1" Coppersetter Standard Pit Setting | W-1 | W-1 |
Water Meter Locations | W-2 | W-2 |
Typical 6" Fire Hydrant Setting | W-3 | W-3 |
Fire Hydrant Locations | W-4 | W-4 |
1"-2" Curb Stop C.I. Box Assembly | W-5 | W-5 |
Typical Frost Free Blowoff Assembly | W-6 | W-6 |
1" Air Relief Assembly | W-7 | W-7 |
Approved A.C. Main Replaced Crossing | W-8 | W-8 |
Thrust Blocking | W-9 | W-9 |
Thrust Block Bearing Area | W-10 | W-10 |
Pipe Bedding and Backfill for Water Mains | W-11 | W-11 |
Cast Iron Valve Box -Two Piece | W-12 | W-12 |
Valve Box Adjustments | W-13 | W-13 |
2" Coppersetter Standard Pit Setting | W-14 | W-14 |
4" & Larger Domestic Meter Vault Setting | W-15 | W-15 |
4" & Larger Service Setting, Irrigation Vault | W-16 | W-16 |
4" & Larger Domestic Service Vault Setting | W-17 | W-17 |
Pressure Sustaining Valve Assy. | W-18 | W-18 |
Pressure Reducing Station Assy. | W-19 | W-19 |
RPBA Premise Isolation, Std. | W-20 | W-20 |
RPBA Premise Isolation, Alt. | W-21 | W-21 |
Approved Atmospheric Vacuum Breaker Installation | W-22 | W-22 |
Approved Pressure Vacuum Breaker Assembly | W-23 | W-23 |
4" or Larger DC in Vault | W-24 | W-24 |
Approved 1" & 2" DC for Premise Isolation | W-25 | W-25 |
Approved DC for Irrigation System | W-26 | W-26 |
Approved Air Gap | W-27 | W-27 |
Monitoring Well Modifications | W-28 | W-28 |
Valve Operating Nut Extension | W-29 | W-29 |
24" Manhole Cover for Meter Vault | W-30 | W-30 |
Typical Approved RP for Irrigation System | W-31 | W-31 |
Approved RP for Building Isolation | W-32 | W-32 |
1" & 2" Service Reconnect | W-33 | W-33 |
Water Main Flushing Chart | W-34 | W-34 |
Approved Pressure Testing Method | W-35 | W-35 |
Allowable Leak Loss Table | W-36 | W-36 |
Approved RP for Premise Isolation | W-37 | W-37 |
Typical Approved DC for Building Isolation | W-38 | W-38 |
Service Abandoned at Corp Stop - IPS & PJ | W-39 | W-39 |
Service Abandoned at Corp Stop - Copper | W-40 | W-40 |
Abandoning AC Pipe Direct Tap Corp Stop | W-41 | W-41 |
Approved RP for Basement Isolation | W-42 | W-42 |
Approved DC for Basement Isolation | W-43 | W-43 |
Approved Large RP for Building Isolation | W-44 | W-44 |
Approved Large RP for Basement Isolation | W-45 | W-45 |
Approved Large DC for Building Isolation | W-46 | W-46 |
Approved Large DC for Basement Isolation | W-47 | W-47 |
PNWS - AWWA RP Discharge Rates | W-48 | W-48 |
1" Sample Station Assembly | W-49 | W-49 |
Automatic Flushing Device | W-50 | W-50 |
Splice Kit Installation | W-51 | W-51 |
4" and Greater Hot Tap | W-52 | W-52 |
Bollards | W-53 | W-53 |